13

PTZ receiver preset position programming

If a PTZ receiver or a KTA-12 series PTZ dome is equipped for preset camera positioning (P option), the
receiver can store 10 preset positions in its nonvolatile memory. You can call each preset position individually
and include each in a preset tour (camera automatically pans, tilts, zooms, and focuses through a series of
preset positions).

To program presets, complete the steps in

System component configuration

on page 10, press 2 at the

component programming selection menu (Figure 21 on page 10), then do the following (for all cameras):

1. and

PTZ receiver configuration

on page 11 to access the receiver site selection display.

2. At the receiver setup display (Figure 23 on

page 11), press 2 to begin receiver setup.

3. In the receiver site selection menu

(Figure 30), use the numerical keys to select
the PTZ receiver site to be programmed. The
next display will appear.

Figure 30. Receiver site selection display

4. At the receiver setup display (Figure 31),

press 2. The next display will appear.

5. Use the PTZ and focus keys to move the

camera to the desired position.

Figure 31. Receiver setup menu display

6. At the preset position display (Figure 32),

assign a preset number (one or two digits
depending on the receiver type and largest
preset number) using one of these methods:

a. If the position won’t be included in the

preset tour, enter the preset number. A
tone will sound to acknowledge that the
position has been entered, and the
display will return to Figure 32.

b. If the position will be included in the

preset tour, enter the preset number and
hold the last digit until a tone sounds.
The display in Figure 33 will appear.

Figure 32. Preset position display

7. At the dwell time display (Figure 33), enter

the amount of time the camera should remain
at the position (1 to 31 seconds). The display
will return to Figure 32 to allow you to enter
the next position.

8. Repeat the previous two steps for each

additional preset position. When you are
done, press Seq to exit to the receiver site
selection menu (Figure 30 on page 13)

Figure 33. Preset dwell time display

ENTER RECEIVER SITE
NUMBER 000 SEQ=EXIT

1=SETUP 2=PRESETS
SEQ=EXIT

CAM 000 POSITION? - -
(00-63) SEQ=EXIT

CAM 000 DWELL --
(01-31 SEC) SEQ=EXIT