I/o box connections, Rj-cable connections, Figure 7. rj-cable connections to the i/o box – Interlogix KTD-405 Series User Manual User Manual

Page 16

Advertising
background image

KTD-405/KTD-405A/KTD-405-2D Controller Keypad

User Manual

12

I/O box connections

RJ-cable connections

The RJ-cable connections make new installations or additional devices easy to connect. If you are replacing an
old phone-style I/O box in an existing installation, you can use the existing twisted-pair wires (STP for RS-485
and UTP for RS-422), if desired. See

Twisted-pair connections

on page 13.

Adhere to all installation guidelines while making connections, including your local codes and those provided
in

Installation guidelines

on page 8.

Figure 7. RJ-cable connections to the I/O box

POWER

12 VDC

BIAS

SWITCH

78

9
10

6

5

3

2

14

RS485

A
B
A
B

+

AUDIO

KEYPAD

RS485

RS485

A
B

RS422 IN

RS422 OUT

SPEAKER SHIELD

SPEAKER

REMOVABLE

TERMINAL STRIP

EARTH GROUND

1 2 3 4 5 6 7 8

Pin 1: RS-485 shield

Ground one end only;
preferably at mux/
DVMRe.

Multiplexer or DVMRe

Observe polarity for:

• audio
• RS-422
• RS-485
• 12 VDC power. Transformer must have a positive

center-polarity plug

Note: When using multiple keypads, you can

connect CyberDomes and other receivers to the
RS-422 output from any keypad.

RS-485 (optional RJ45
connection*)

For DVMRes, multiplexers,
ProBridges, and additional
KTD-405 I/O boxes.

KEYPAD

Black RJ45 (

) control

cable. (Use the new cable
with the new I/O box, not the
old silver crossover RJ45
cable.)

Audio

Silver RJ11

cable from

keypad (provided only with
the KTD-405A).

Crossover Straight-through

Pin 3: RS-485A

Pin 6: RS-485B

Pins 2, 4, 5, 7, 8 are
not connected.

* The installer supplies the

optional RJ45 RS-485
cables with the stated
pinouts (an RS-485
connection is also
available on the terminal
strip).

RS-485 (optional RJ45 RS-
485 connection*)

For DVMRes, multiplexers,
ProBridges, and additional
KTD-405 I/O boxes.

Advertising