Supervisor programming, Figure 17. supervisor programming menu tree – Interlogix KTD-405 Series User Manual User Manual

Page 26

Advertising
background image

KTD-405/KTD-405A/KTD-405-2D Controller Keypad

User Manual

22

Supervisor programming

As explained in

Entering programming modes

on page 21, to enter the supervisor menus, from the ENTER

PROGRAMMING CODE menu, press 1-4-7-6-seq.

Note: This is the default factory supervisor programming code sequence. After you install your KTD-405 keypad, be sure to

change the supervisor programming code as soon as possible to avoid security problems. To change the programming code,
see Figure 27 on page 26

of this menu. This is a critical number since it is needed to change any of the access codes. Be sure

to store the new number in a safe place. If the number is lost, GE Security technical support can help you reset the keypad to
factory defaults. All keypad setup information will be lost.

1. At the first menu in supervisor programming mode, you have the option to erase the keypad’s

nonvolatile memory and reload factory values. If you chose YES, you have these further options:

RESET ALL. Resets all stored settings to factory default.

RESET ALL BUT TITLES. Retains the zone titles, but sets everything else to factory defaults.

CAMERA. Access the camera you want to reset before you enter the supervisor programming.
Selecting this will send a reset to the camera. This is for resetting or restarting GE PTZs, not for
clearing settings. (16x, CyberDome2, and Legend)

Pressing forwards you through programming without changing set parameters.

To skip this menu and go to the next, press - or .

Figure 17. Supervisor programming menu tree

Note: All PTZ's that are capable will reset when you send this command.

RESET TO DEFAULTS?
NO

PARTIAL. ARE
YOU SURE?

RESET CAMERA X ?

ARE YOU SURE?

COMPLETE. ARE
YOU SURE?

1 = RESET ALL BUT
TITLES

INITIALIZING
DEFAULTS

KEYPAD ADDRESS: 99

(01-99)

NEXT

Advertising