174

Transmission of Command

Transmits a command represented by a single ASCII code to the OBR. Various options including

"Readout mode", "Data transfer format", etc., can be set for this transmission. This setup does not

have to be made each time the power is turned on if it is written in the EEPROM.

For information about the setup procedure refer to "Setting Operation Mode".

SYNTAX

#include "obrlib.h"

int OBR_Send (char Cmd);

INPUT

Cmd = Transmission command (refer to the Command List.)

OUTPUT

= 0 : Normal termination

= 1 : Transmission buffer-full error

= 2 : CTS does not turn to ON.

= 3 : Receives NAK from scanner.

= 4 : No response from scanner

Note :

Do not read another barcode during command transmission to the OBR.

Acknowledgment of Received Data

Returns the number of characters in the first barcode stored in the reception buffer.

SYNTAX

#include "obrlib.h"

int OBR_Stat();

INPUT

None

OUTPUT

The absolute value shows the number of characters in the received barcode (not

including a CR). The sign indicates whether the data is a complete barcode or not.

< 0 Incomplete barcode

> 0 Complete barcode

Note :

After acknowledging that the barcode has been received, read it using the OBR_Read function.