197

8.5.1 Communication Parameter Setup Command (/L={,,,}

Sets up command parameters according to the command specified next to "=". If the communication

environment command needs to be specified, this command must precede it.

Command Specification Method

FLINK /L={

maximum IrDA speed, wait time until the connection is established, data

transmission/reception wait time}

Always place the parameters between a pair or braces ("{ }"). Parameters do not need to be

specified, however, commas (,,,) must be specified. If a parameter is not specified, the corresponding

default values will be used.

IrDA communication speed

Input parameter

Baud rate (bps)

Remark

2400

2400

9600

9600

19 K

19200

38 K

38400

57 K

57600

115 K

115.2 K

576 K

576 K

1 M

1 M

4 M

4 M

Default value

Wait time until the connection is established

 Specify between 0 and 3600 seconds.
 If "0" is specified, the application will wait until the connection is established.
 The default value is 1800 seconds.

Data transmission/reception wait time

 Specify between 0 and 600 seconds.
 If "0" is specified, the application will wait until the communication function is normally or

abnormally terminated.

 The default value is 300 seconds.