KERN & SOHN SFB 300K-1LM User Manual

Page 32

Advertising
background image

SFB-BA-e-1324

32

 Press the navigation keys (See chap. 2.1.1) to enter the

upper limit, e.g. 1,100 kg; the currently enabled digit will be
flashing.

 Confirm input by

.

 Press

repeatedly until

is displayed.

 Press

and the current setting for the acoustic signal will

be shown.

 Select desired setting (no, ok, ng) by

.

 Confirm input by

.


 Press

; weighing system is in tolerance weighing mode.

From here evaluation takes place whether the goods to be
weighed are within the two tolerance limits.

Weighing with tolerance range

 Tare when using a weighing container.

 Put on goods to be weighed, tolerance control is started. The signal lights

indicate whether the load is within the two set limits.

Load below specified
tolerance

Load within specified
tolerance

Load exceeds specified
tolerance

Red signal light

next to „-“ ON illuminated

Green signal light

next to „„ illuminated

Red signal light

next to „+“ ON illuminated

The tolerance control is not active when the weight is under 20d.

To delete limits, enter “00.000 kg“.