KERN & SOHN SFB 300K-1LM User Manual

Page 34

Advertising
background image

SFB-BA-e-1324

34

 Press

; weighing system is in tolerance weighing mode.

From here evaluation takes place whether the goods to be
weighed are within the two tolerance limits.

Weighing with tolerance range

 Set item weight, see chap. 7.10.

 Tare when using a weighing container.

 Put on goods to be weighed, tolerance control is started. The signal lights

indicate whether the load is within the two set limits.

Load below specified
tolerance

Load within specified
tolerance

Load exceeds specified
tolerance

Red signal light

next to „-“ ON illuminated

Green signal light

next to „„ illuminated

Red signal light

next to „+“ ON illuminated

The tolerance control is not active when the weight is under 20d.

To delete limits, enter „00000 PCS“.