REMOTE TEMPERATURE CONTROLS

The supplied Remote Main Control allows the customer to control the hot water supply temperature and

will display certain fault codes in the event the water heater needs servicing. If used without the Remote

Main Control connected, the residential models (IGE-199R-10N,10X) have a fixed temperature setting of

120°F and the commercial models (IGE-199C-5N, 5X) have a fixed temperature setting of 140°F.

Residential Models:

The Remote Control inside the carton is intended for installation in the kitchen, utility, or laundry area of a

home. The adjustment range for all residential water heater controls is 98-160°F.

DANGER

Hotter water increases the risk of scald injury. Scalding may occur within 5 seconds at a temperature

setting of 135°F (57°C). To protect against hot water injury, install a ASSE approved mixing valve in the

water system. This valve will reduce point of discharge temperature by mixing cold and hot water in

branch water lines. A licensed plumbing professional or local plumbing authority should be consulted.

NOTICE

This water heater is equipped with an energy cut out device to prevent overheating. Should overheating

occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance and call a

qualified service agency.

CAUTION

This water heater, when set at a lower temperature setting is not capable of producing hot water of

sufficient temperature for sanitizing purposes.

Always check water temperature by hand before entering the shower or bath. The temperature may have

been changed.

Test the temperature of the water with your hand or elbow before placing a child in the bath or shower.

Do not leave a child or an infirm person in the bath unsupervised.

In addition, all models may have up to two optional remote controls (P/N 239-44509-00) installed in

bathrooms or other remote locations to control the temperature for showers and sinks. When these

controls are used, depressing the Priority Button will override the Main Remote Control and display the

setpoint of the Remote Control in use. All the remote Remote Controls will display fault codes in the

event the water heater needs service.

NOTICE

No more than three temperature controls may be connected to one EVERHOT® water heater.

NOTICE

The default temperature setting displayed for residential controls that will appear when the water heater is

first connected to the electrical supply or in the event of a power interruption is 120°F.

Before installing the remote controls, determine the most convenient locations(s). When deciding on the

best location for the remote controls, please consider the following items:

1. Place the controls out of reach of small children.

2. Avoid locations where the control(s) will become hot, such as over the stove, near the oven, or

other heat sources.

3. Avoid direct sunlight. (The digital readout can be difficult to read in direct sunlight).

4. Avoid areas where the remote can be splashed with cooking water, oil, or sauce.

5. The remote control operates with low voltage, 12 volts DC.