CAUTION

In climates where below freezing temperatures may occur, the water heater must be drained when

power is off to the water heater to prevent freeze damage to the heat exchanger. Drain solenoids

are recommended to prevent freeze damage during power failures in cold climate regions.

TURNING OFF THE WATER HEATER FOR AN EXTENDED PERIOD OF TIME

If the EVERHOT® water heater is to be turned off for an extended period of time, the following steps

should be taken.

1. Turn the gas shutoff valve on the gas supply inlet to the OFF position (see operating instructions).

2. Disconnect the electrical supply to the water heater.

3. Shut off the cold water supply to the water heater and open the drain valve to drain the water

heater. If the water heater was installed with drain solenoid freeze protection, the water heater

will drain automatically when power is disconnected.


TEMPERATURE ADJUSTMENT

DANGER

Hotter water increases the risk of scald injury. Scalding may occur within 5 seconds at a temperature

setting of 135°F (57°C). To protect against hot water injury, install a ASSE approved mixing valve in the

water system. This valve will reduce point of discharge temperature by mixing cold and hot water in

branch water lines. A licensed plumbing professional or local plumbing authority should be consulted.

CAUTION

This water heater, when set at a lower temperature setting is not capable of producing hot water of

sufficient temperature for sanitizing purposes.

Always check water temperature by hand before entering the shower or bath. The temperature may have

been changed.

NOTICE

This water heater is equipped with an energy cut out device to prevent overheating. Should overheating

occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance and call a

qualified service agency.

NOTICE

The lower the temperature setting, the greater the energy efficiency to heat the water. Lower water

temperatures also extend the heat exchanger life. Remember, no water heating system will provide

exact temperatures at all times. Allow a few days of operation at this setting to determine the correct

temperature setting consistent with the requirements for the installation.


Residential Models (see Figure 10):

1. The outlet water temperature of the EVERHOT water heaters is adjusted using the Remote Main

Control supplied in the water heater carton. When additional Remote Controls are installed, the

temperature can only be adjusted on the remote control that has the Priority Indicator Light

glowing. The temperature displayed on the control in use will also be displayed on all the other

remote controls.