First aid for scalds, Warning – LAARS IGE-199C - Installation Manual User Manual

Page 34

Advertising
background image

APPROXIMATE

TIME/TEMPERATURE

RELATIONSHIPS IN SCALDS

120°F (49°C) More than 5 minutes

125°F (52°C) 11⁄2 to 2 minutes

130°F (54°C) About 30 seconds

135°F (57°C) About 10 seconds

140°F (60°C) Less than 5 seconds

145°F (63°C) Less than 3 seconds

About 11⁄2 seconds

150°F (66°C)

About 1 second

155°F (68°C)

FIRST AID FOR SCALDS

1. Remove all wet clothing quickly. Wet clothing retains the heat.

2. Apply cold water to burned area for 30 minutes to reduce the heat in the skin and prevent deeper

burning. Never use butter, oils, or ointment to cover the burn. They may retain the heat.

3. Use a blanket to keep the scalded person warm.

4. Seek medical advice.


ERROR MESSAGES ON REMOTE TEMPERATURE CONTROL DISPLAY

The LAARS EVERHOT® tankless water heaters have the ability to monitor and display any

operating faults on the remote temperature control display. The error messages will display on the

monitor and will assist in servicing the water heater. The following is a listing of the error codes that may

flash on the remote monitor in case of a malfunction with the water heater. Please quote the code

displayed when calling for service.

Code

Displayed

Fault Remedy

10

Air supply or exhaust blockage

Check for a restriction in the exhaust vent.

11

No Ignition

Check to make sure the gas supply is on to the

water heater.

12

Flame Failure, grounding failure

Make sure gas is turned on at the water heater;

check for obstructions in exhaust vent.

14

Thermal Fuse

Heat exchanger overheated

16 Over

Temperature

Warning Excessive temperatures, wrong dip switch

setting, incorrect manifold pressure or gas type.

32

Outlet water temperature faulty

Outlet sensor or wiring may be defective

33

Heat exchanger outlet water temperature

faulty

H.E. outlet sensor or wiring may be defective.

34

Combustion air sensor faulty

Thermistor or wiring faulty

52

Modulating Solenoid Valve signal

abnormal

Check gas control and wiring

61

Combustion Fan Failure

Combustion fan or wiring faulty

71

Solenoid Valve Driving Circuit Faulty

Check all gas solenoids and wiring

72

Flame Sensing Device Faulty

Lack of flame sense – check flame rod and

wiring connections.

LC

Scale build-up in Heat Exchanger

Build up of lime scale in heat exchanger –

needs to be flushed.

(00)

(When checking maintenance code

history, “00” is substituted for “LC”).

If any of the above error codes are seen flashing on the remote display, call for service

.

WARNING

Failure to remedy faults may result in severe burns, scalds, and/or death.

34