LAARS IGE-199C - Installation Manual User Manual
Page 5
SECTION II: SPECIFICATIONS
Max. Flow Rate @ Degree Temperature Rise
Max.
Input
Rating
Btu/hr.
Min.
Input
Rating
Btu/hr.
Temp Rise
40
°F
60
°F
80
°F
100
°F
120
°F
Model No.
140
°F
5
Flow Rate vs Temperature Rise Curve for EVERHOT
® IGE model series
0
1
2
3
4
5
6
7
8
9
0
25
50
75
100
125
150
ΔT – Temperature Rise (°F)
Max. Flow (gpm)*
*Note: The maximum flow is based upon a minimum water pressure of 30 PSI
Flow Rate
Gal/Min.
7.3 5.9 4.2 3.3 2.8 2.4
IGE-199R-10N
IGE-199R-10X
IGE-199C-5N
199,000
15,000
First Hour
Supply
Gal/Hr
.
438 354 252 198 168
IGE-199C-5X
144
Max. Flow Rate @ Degree Temperature Rise
Model No.
Max.
Input
Rating
kW/hr.
Min.
Input
Rating
kW/hr.
Temp Rise
22
°C
33
°C
44
°C
56
°C
67
°C
78
°C
Flow Rate
Liters/
Min.
27.6 22.3 15.9 12.5 10.6 9.1
IGE-199R-10N
IGE-199R-10X
IGE-199C-5N
IGE-199C-5X
58.3
4.4
First Hour
Supply
Liters/Hr
.
1656
1338