Warning, Caution, Danger – LAARS IGE-199C - Installation Manual User Manual

Page 9

Advertising
background image

9



WARNING

WARNING

This water heater is suitable for potable water heating only. DO NOT use this

water heater for space heating or combination space heating/domestic water
heating.

This water heater is not suitable for use in pool or spa applications.

The water heater must be installed outdoors. Failure to properly install this

water heater outdoors may result in property damage, personal injury, o

r

death. Refer to the installation of the water heater in this installation and
instruction manual for details on the location and installation outdoors. DO
NOT INSTALL INDOORS.

WARNING

Pressure relief valve discharge piping must be piped near the ground or drain to eliminate

potential of severe burns. Insulate and use electrical heat tape around the discharge drain

pipe in any area where freezing could occur. Do not install any shut-off valves, plugs or caps

to the pressure relief valve or discharge piping.

CAUTION

If building cold water supply has a back-flow preventer, check valve or water meter with check

valve, provisions for thermal expansion of water in the hot water system must be provided.

DANGER

Temperature setting should not exceed safe temperature at fixtures. See water temperature

control warnings in the “Temperature Adjustment Section” of this Installation and Operating

Instruction Manual. If higher preheat temperatures are necessary to obtain adequate booster

output, add an ASSE approved mixing valve for hot water supplied to fixtures.

UNPACKING


INSPECT SHIPMENT

carefully for any signs of damage.

1. All equipment is carefully manufactured, inspected and packed.

2. Any claims for damage or shortage in shipment must be filed immediately with the shipping

c

ompany and noted on the Bill of Lading.

WATER HEATER LOCATION:

1. The IGE series water heaters must be installed outdoors. Refer to figure 1 and table 1 (Section

IV) in this Installation and Instruction Manual for minimum installation clearances before choosing

a final location for the water heater.

2. The water heater must be installed on a wall capable of supporting at least 50 pounds (23 Kg).

Locate the water heater at a height convenient for servicing and above the reach of small

children.

3. Minimum clearance to combustible material is 12” (30.5 cm) from the Top, 24” (61 cm) from the

Front, 0” from the Rear, 6” (15.2 cm) from the Sides, and 12” (30.5 cm) from the Bottom of this

water heater. An optional recess box is available for installing the water heater recessed in an

outside wall and enclosing the piping (see features section). When the water heater is installed in

a recess box, the clearances from the top, bottom, sides, and back surfaces of the recess box to

combustible materials are 0”. The clearance from combustibles from the front of the recess box

is 24” (61 cm). Contact your Laars distributor for information on obtaining and installing

the water heater in a recess box.

Advertising