INSTALLATION REQUIREMENTS/SPECIFICATIONS

Page 2-13

Parameter

Typical

Minimum

Maximum

Transmitter Peak
Wave Length

1300 nm

1270 nm

1330 nm

Spectral Width

60 nm

-

100 nm

Rise Time/

3.0 nsec

2.7 nsec

5.0 nsec

Fall Time

2.5 nsec

2.2 nsec

5.0 nsec

Duty Cycle

50.1%

49.6%

50.7%

Bit Error Rate:

Better than 10

-10

Note: The transmitter power levels given above are Peak Power

Levels after optical overshoot. You must use a Peak Power Meter to
correctly compare the values given above to those measured on any
particular port. If you are measuring power levels with an Average
Power Meter, add 3 dBm to the average power measurement to
correctly compare the average power values measured to the values
listed above (i.e. -33.5 dBm average + 3 dB = -30.5 dBm peak).

Receive

Sensitivity

dBm

Less Power

More Power

-40

-35

-30

-25

-20

-15

-10

-5

0

Maximum

Receive

Input Power

Transmitter Power*

(At 25

°

C into

8.3/125

µ

m fiber)

Minimum Sensitivity (-30.0)

Typical Sensitivity (-31.0)

Maximum Sensitivity (-36.0)

Maximum Receive Input (-6.99)

Typical Receive Input (-7.5)

Minimum Receive Input (-9.72)

Maximum Transmit Power (-12.0)

Typical Transmit Power (-15.5)

Minimum Transmit Power (-21.0)

* Transmit Power Typical Power Minimum Power Maximum Power
Coefficient
(See Note Below)-0.15dBm/

°

C -0.12 dBm/

°

C-0.18 dBm/

°

C