Cabletron Systems SEH-34 User Manual

Page 29

Advertising
background image

INSTALLATION REQUIREMENTS/SPECIFICATIONS

Page 2-17

JAM Output:

Collisions are propagated
through the network using the
JAM signal of an alternating
pattern of 1's and 0's in
accordance with 802.3
specifications for a repeater unit.

Fragment Extension:

Packet fragments are extended to
a minimum of 96 bits using the
JAM [1,0].

Fault Protection:

Each segment will disconnect
itself from the other segments if
32 consecutive collisions occur, or
if the collision detector of a
segment is on for longer than
approximately 110

µ

s. This fault

protection will reset
automatically after one packet is
transmitted/received onto the
fault protected segment without
causing a collision.

POWER SUPPLY REQUIREMENTS

Note: The SEH has a universal power supply. This unit allows you to
use an input power from 90 to 264 VAC, 47-63 Hz.

The power supply has two outputs of +5 volts and +12 volts. The
maximum output power is 20 watts and the minimum efficiency is
65% under all conditions of line at full load. The minimum and
maximum load current from each output is shown below.

Output

Min. Load

Max. Load

Max Power

+5 Volts

0.50 Amps

3.0 Amps

15 Watts

+12 Volts

0.05 Amps

1.0 Amps

12 Watts