TROUBLESHOOTING

Page 5-3

Figure 5-1. LANVIEW LEDs

PWR (Green)
When this LED is on it indicates that the SEH is receiving power. If
this LED is off, it indicates a loss of input power. Check the input
power source (circuit breaker, fuse, etc.). If the proper source power is
present, the problem could be with the SEH.

MGMT (Green Flashing)
This LED flashes when an intelligent hub manages the SEH. If this
LED does not flash, an intelligent hub is not managing the SEH. If
you connect an intelligent hub to the SEH and the LED does not flash,
inspect the HubSTACK Interconnect cables for proper connections.

PWR

MGMT

CLN

E
1

E
2

RCV
LNK

RCV
LNK

HubSTACK

10BASE-T HUB

WITH

LANVIEW®

SEH-24

24 23 22 21 20 19 18 17 16 15 14 13

12 11 10 9 8 7 6 5 4 3 2 1

24X

12X

LED NAME

PWR
(Power)

MGMT
(Management)

CLN
(Collision)

RCV
(Receive)

LNK
(Link)

LED COLOR

Off
Green (Solid)

Green (Flashing)
Off

Red

Yellow (Flashing)
Off

Green
Off

DEFINITION

No Power
Power

SEH Managed by an Intelligent Hub
SEH Not Managed

Collision

SEH is Receiving Data
No Activity

Link Established
No Link