OUTSIDE TERMINAL WIRING EXAMPLES

The information on the following pages cover the most common wiring options:

• Supplied Momentary Push Button

• Discrete Extend and Retract for switch or dry contacts

• 12 Volt out supply

• 24 Volt out supply

• Two dry contact closures

• Service Extend

CAUTION: Closing the unit while the projector is running may
cause premature bulb failure and may damage both the lift and pro-
jector.

Push Button

Supplied Single Pole Single Throw (SPST) Switch
Using Internal 24VAC Power Supply

a.

Connect the green jumper wire (supplied) to terminals 1 & 5
(see Figure 13).

b. Connect the SPST switch (supplied) to terminals 2 & 6.

Supplied SPST Switch Using Internal 12VDC Power Supply

a.

Connect the green jumper wire (supplied) to terminals 5 & 9
(see Figure 14).

b. Connect the SPST switch (supplied) to terminals 6 & 10.

Supplied SPST Switch Using External Power Supply

a.

Connect the negative of your power supply to terminal 5 (see
Figure 15).

b. Connect the SPST switch (supplied) to terminal 6 & the pos-

itive of your power supply.

Figure 15. External Power Supply

Figure 14. 12DC Internal

Figure 13. 24VAC Internal