SMART-LIFT 236 Electric Ceiling Lifts

20

SMART LIFT EXTERIOR 14 PIN

TERMINAL FUNCTION DEFINITION

TERMINAL

NUMBER

FUNCTION

DESCRIPTION

WIRING OPTIONS

NOTES

1

24 VOLT AC

24 volt AC output

2

24 VOLT AC

COMMON

24 volt AC common

This is an internal power supply for
powering external devices & Remote
Controllers.

Chief Mfg. offers the RC-10 Radio
Frequency Remote Controller which runs
off of this power supply.

3

RETRACT

Retracts unit to preset travel limit.

Travel limits may be adjusted by

customer within a preset maximum

range.

If using Latching Switch, be sure to
disengage Switch prior to initiating any
other function.

4

EXTEND

Extends unit to preset travel limit.

Customer within a preset maximum

range may adjust travel limits.

Momentary or Latching contact to
Ground terminals 9, or 11.

If using Latching Switch, be sure to
disengage Switch prior to initiating any
other function.

5

EXTEND/

RETRACT
COMMON

Used in conjunction with

Extend/Retract when using an

external power source to initiate

movement.

NOT TO BE USED AS GROUND FOR
FUNCTION OTHER THAN
EXTEND/RETRACT TERMINAL 5.

6

EXTEND/

RETRACT

Initiates movement if lift is static, or

stops movement if lift is in motion.
Direction of travel will be opposite

of last direction of travel.

To Operate using Internal Power
Source
Connect terminals 9 & 5 with
Jumper Wire. Connect
Momentary Switch to terminal
10. Connect other line of
Momentary Switch to terminal 6.

To Operate using External Power
Source
Connect External Power Supply’s
Common to terminal 5. Connect
initiating signal to terminal 6.

Function operates on momentary switch
only.

Operating range is 5 – 30 Volts AC or DC.

7

RETRACT

ERROR

Immediately reverses direction of

travel when triggered while unit is

retracting.

8

EXTEND

ERROR

Immediately reverses direction of

travel when triggered while unit is

extending.

Momentary contact to Ground
terminals 9, or 11.

Chief Mfg. offers the SS-10 Pressure
Sensitive Safety Strip to provide this
function.
Please specify how many inches required
to span entire pinch zone.
The SS-10 must be ordered with the ST-15
Terminals.

9

GROUND

Ground

10

12 VOLT DC

12 volt DC

This is an internal power supply for
powering external devices &/or used for
initiating specific functions
(Extend/Retract 6).

11

Service Extend

Extends unit to maximum limit,

bypassing normal-use travel setting

Often used for servicing projectors

in ceiling lifts.

Momentary or Latching contacts
to Ground terminals 3, 10, 13, or
20

Feature not available on all models.

If using Latching Switch, be sure to
disengage Switch prior to initiating any
other function