Instruction Manual

SMART-LIFT 236 Electric Ceiling Lifts

11

EXTEND

Extends unit to preset travel limit.

Customer within a preset maximum

range may adjust travel limits.

If using Latching Switch, be sure to
disengage Switch prior to initiating any
other function.

12

RETRACT

Retracts unit to preset travel limit.

Travel limits may be adjusted by

customer within a preset maximum

range.

Momentary or Latching contact to
Ground terminals 3, 10, 13, or 20.

If using Latching Switch, be sure to
disengage Switch prior to initiating any
other function.

13

GROUND

Ground

14

EXTEND

ERROR

Immediately reverses direction of

travel when triggered while unit is

extending.

15

RETRACT

ERROR

Immediately reverses direction of

travel when triggered while unit is

retracting.

Momentary contact to Ground
terminals 3, 10, 13, or 20.


Chief Mfg. offers the SS-10 Pressure
Sensitive Safety Strip to provide this
function.
Please specify how many inches required
spanning entire pinch zone.
The SS-10 must be ordered with the ST-15
Terminals.

16

EXTEND

LIMIT

RELAY

17

EXTEND

LIMIT

RELAY

COMMON

Closes set of internal dry contacts

when unit reaches full extension.

RATED FOR 1 AMP @ 24 VOLTS

18

RETRACT

LIMIT

RELAY

19

RETRACT

LIMIT

RELAY

COMMON

Closes set of internal dry contacts

when unit reaches full retraction.

RATED FOR 1 AMP @ 24 VOLTS

20

GROUND

Ground

1.0 AMP@30VDC
0.5 AMP@125VAC
0.3 AMP@60VDC

1.0 AMP@30VDC
0.5 AMP@125VAC
0.3 AMP@60VDC