SMART LIFT INTERIOR BOARD BOX

TERMINAL FUNCTION DEFINITIONS

TERMINAL

NUMBER

FUNCTION

DESCRIPTION

WIRING OPTIONS

NOTES

1

24 VOLT AC

24 volt AC output

2

24 VOLT AC

COMMON

24 volt AC common

This is an internal power supply for
powering external devices & Remote
Controllers.

Chief Mfg. offers the RC-10 Radio
Frequency Remote Controller which runs
off of this power supply.

3

GROUND

Ground

4

12 VOLT DC

12 volt DC

This is an internal power supply for
powering external devices &/or used for
initiating specific functions
(Extend/Retract 5 or Voltage Sensor 7).

5

EXTEND/

RETRACT

Initiates movement if lift is static, or

stops movement if lift is in motion.
Direction of travel will be opposite

of last direction of travel.

Function operates on momentary switch
only.

Operating range is 5 – 30 Volts AC or DC.

6

EXTEND/

RETRACT

COMMON

Used in conjunction with

Extend/Retract when using an

external power source to initiate

movement.

To Operate using Internal Power
Source
Connect terminals 3 & 6 with
Jumper Wire. Connect
Momentary Switch to terminal 4.
Connect other line of Momentary
Switch to terminal 5.

To Operate using External Power
Source
Connect External Power Supply’s
Common to terminal 6. Connect
initiating signal to terminal 5.

NOT TO BE USED AS GROUND FOR
FUNCTION OTHER THAN
EXTEND/RETRACT TERMINAL 5.

7

VOLTAGE

SENSOR

When terminal senses voltage, unit

will extend.

When terminal senses cessation of

voltage, unit will retract.

Operating range is 5 – 30 Volts AC or DC.

8

VOLTAGE

SENSOR

COMMON

Used in conjunction with Voltage

Sensor when using an external

power source to initiate movement.

Voltage Sensing
Connect positive lead to terminal
7. Connect Ground of switching
device to terminal 8.

Single-Pull/Throw Latching
Switch
Connect terminals 3 & 8 with
Jumper Wire. Connect first
Switch Terminal to terminal 4.
Connect other Switch Terminal to
terminal 7.

NOT TO BE USED AS GROUND FOR
FUNCTION OTHER THAN VOLTAGE
SENSOR TERMINAL 7.

9

SERVICE

EXTEND

Extends unit to maximum limit,

bypassing normal-use travel setting.

Often used for servicing projectors

in ceiling lifts.

Momentary or Latching contact to
Ground terminals 3, 10, 13, or 20.

Feature not available on all models.

If using Latching Switch, be sure to
disengage Switch prior to initiating any
other function.

10

GROUND

Ground