TROUBLESHOOTING

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

LIFT DOES NOT RESPOND

12V TRIGGER OPTION BEING USED

NORMAL OPERATION

SEE NOTES ON 'LOW VOLTAGE SENSING' PAGE#16

NO POWER

VERIFY POWER TO LIFT

FUSE BLOWN

CHECK FUSE ON CONTROL BOX

LIMIT SWITCH

CALL CHIEF FOR VERIFICATION

FAILED CONTROL BOX

CALL CHIEF FOR VERIFICATION

LIFT WILL NOT LOWER/RAISE

CONTROL BOX CLICKS
MOTOR SILENT

OVERHEATED MOTOR

LET MOTOR COOL FOR 5-15 MINUTES.

FAILED MOTOR

CALL CHIEF FOR VERIFICATION

LIFT WILL NOT LOWER/RAISE

CONTROL BOX CLICKS
MOTOR HUMS

BINDING MECHANISM

MAKE SURE CABLES ARE ROUTED PROPERLY

SEE 'INSTALL AND ROUTE CABLES' PAGE#11

FAILED MOTOR

CALL CHIEF FOR VERIFICATION

FAILED CONTROL BOX

CALL CHIEF FOR VERIFICATION

PROJECTOR CRADLE / BOTTOM
PANEL LOWER ON ONE SIDE.

NORMAL OPERATION

A DIFFERENCE OF UP TO 3/16" WITHIN THE FINAL 4" OF
TRAVEL IS NORMAL

WHEN THE LIFT IS EXTENDED BEYOND 4", UP TO 3/8"
DIFFERENCE IS NORMAL

LIFTING LINKS OUT OF ADJUSTMENT

CALL CHIEF

LIFTING BRACKET DAMAGED

CALL CHIEF

PROJECTOR CRADLE / BOTTOM

PANEL SIGNIFICANTLY LOWER ON
ONE SIDE

DAMAGED HINGE ASSEMBLY

CALL CHIEF

LIFTING BRACKET DAMAGED

CALL CHIEF

HOOKS ON LIFTING BRACKET DO

NOT CATCH THE ROLLERS ON THE
PROJECTOR CRADLE.

BINDING MECHANISM

MAKE SURE CABLES ARE ROUTED PROPERLY

SEE 'INSTALL AND ROUTE CABLES' PAGE#11

LIFTING LINKS OUT OF ADJUSTMENT

CALL CHIEF

LIFTING BRACKET DAMAGED

CALL CHIEF

DAMAGED HINGE ASSEMBLY

CALL CHIEF