MICROTEL Series 1000EX Dialer

47

Advanced Configuration Options

Advanced Phone Number Features

z Call Progress Coding Features The Series 1000EX has very powerful call

progress coding features which allow great flexibility in making phone calls to
pagers, fax machines, other dialers, or regular telephones. The following table lists
the different codes which can be used to customize how the dialer will make a call-
out. These codes are used extensively in the following examples.

Telephone Number Escape Codes

Code Command
*0

Tone dial (default)

*1 Pulse

dial

*2 2-Second

Pause

*3

Flash Hook (go on hook for 100 milliseconds)

*4

Wait for Voice or Answer

*5n

Wait for Tone (n seconds)

*6n

Wait for Quiet (n seconds)

*7nn

Set Wait Timer to Abort (if condition does not occur in nn seconds)

*8nn

Set Wait Timer to Continue (if condition does not occur in nn seconds)

*90

Auto Acknowledge this Call

*91 Dial

‘*’

*92 Dial

‘#’

*93nn

Close (Turn ON) Digital Output Channel n

*94n

Set this Call Alternate Message Repeat Count of n

*95n

Set this Call Alternate Voice Interact Delay

*96nn

Open (Turn OFF) Digital Output Channel n

*980 Dial

‘A’

*981 Dial

‘B’

*982 Dial

‘C’

*983 Dial

‘D’

*990 Modem

Callout

*991 Fax

Callout

When entering call progress sequences in telephone numbers, you must first set the
Wait Timer (*7nn or *8nn), then set the specific condition to wait for (*4, *5n, or
*6n). Also, the Wait Timer stays in effect until overridden. So, when programming
your telephone numbers into the dialer, always explicitly set Wait Time-outs (*7nn or
*8nn) before waiting for Tone, Quiet, Voice or Answer detect. The following
example should illustrate: