Microtel Series 1000EX User Manual

Page 57

Advertising
background image

MICROTEL Series 1000EX Dialer

51


Use the following command syntax to review/set disable timers:

0*2nn*

Report disable timer current value

0**2nnDDHHMM*

Set disable timer n


DDHHMM

(00-99 Days, 00-23 Hours, 00-59 minutes)


n=0

This indicates the System Disable Timer. This setting disables all outgoing
calls while this countdown timer is non-zero.


n=1-9

This indicates telephone number n Disable Timer. This disables the dialer
from placing calls to phone number n while this countdown timer is non-
zero.


Examples-

Command:

0**200000105*

Response:

The system disable timer is one hour five minutes.


Command: 0**201010105*
Response:

Telephone number one disable timer is one day one
hour five minutes
.

The Following is an example of use:

The on-call person is going out of town for 3 days. He wishes his family not to be
disturbed while he is gone. The dialer is instructed to skip his phone number during
an alarm call-out sequence. In this case, the command 0**201030405* would
prohibit alarm calls to be placed to phone 1 for 3 days, 4 hours, and 5 minutes
beginning at the time the command is sent.

z Initializing Configuration Data These programming commands configure the

dialer with default data. Before initializing, print or FAX a copy of your dialer’s
current configuration as described in Chapter 3, Operations section.

0**09001973*

Initialize System Data

0**09102846*

Initialize Telephone Data

0**09200534*

Initialize Channel Data

0**09310872*

Initialize Runtime Data


CAUTION: Programmed data will be reset to Defaults. These commands should

only be used if it is necessary to clear out all configuration data.