Modes of operation – Culligan Gold Series User Manual

Page 10

Advertising
background image

Water Meter Mode

In water meter mode, the controller keeps track of the quantity of water that has flowed through the

resin bed. Based on the influent water hardness and the hardness capacity of the resin bed, a service

life expectancy in the quantity of softened water is calculated and programmed into the control.

When the set point is reached, regeneration is triggered. In delay regeneration mode, if the predict

mode is turned on, the average daily water usage will be compared to the remaining capacity

at the regeneration delay time to predict if another day’s water usage can occur before requiring

regeneration. If enough capacity is not present then the regeneration will occur at that time. If the

predict mode is not selected the regeneration will start at time of regeneration. In immediate mode

the regeneration starts when the capacity is exhausted. If time clock backup is set and the capacity

has not been exhausted but the days since last regen is greater than time clock backup, setting the

softener will immediately regenerate.

Aqua-Sensor

®

Mode

The Aqua-Sensor is a conductivity probe that senses when a hardness front passes through the resin

bed. It functions independently of the influent water hardness so therefore, is useful in conditions

when the influent water hardness varies throughout the year. It provides for the most efficient

mode of operation. In addition to sensing when a resin bed is exhausted, it can also be used to

determine when the brine solution is rinsed from the resin bed during the Brine Draw/Slow Rinse

cycle triggering the control to move to fast rinse. This patented feature provides water savings by

optimizing the amount of rinse water required to completely rinse out the resin bed.

Manual Regeneration

Pressing and holding the regen button for 5 seconds will initiate an immediate regeneration. The

beeper will give one beep at the start of manual regeneration (when the motor starts to turn). In delay

mode, pressing and releasing the regen button will light the regen icon for regeneration to occur at

the set delay time. Pressing and releasing the regen button again will turn off the regen icon.

Predict Mode

The Predict Mode is used with the flow meter to determine the optimum regeneration point. Before

the regeneration starts, the control will compare the remaining capacity value with the average daily

water use. If the average daily water usage is less than the reserve capacity, the controller will

wait 24 more hours before regeneration. If the reserve capacity is less than the average daily water

usage, the control will initiate regeneration. This works in delay mode only. At any time, if the total

capacity value is reached, the control will initiate an immediate regeneration.

Efficiency Mode

Water softeners historically use an optimum time range to control the Regeneration cycle steps, with

a minimum and maximum time required to perform each step dependent on the salt being used,

the hardness total and iron level. Culligan typically uses the maximum time range to insure effective

Regeneration. However, if the iron content of the water to be softened is zero, and the hardness level

is less than 20 gpg, Culligan has developed a new set of regeneration times geared to reducing salt

and water usage. These times are defined under a new operating mode coined “Efficiency Mode”.

Compared to the present time values used, these new regeneration times and salt dosages are

considerably less.

Modes of

Operation

10