• Regeneration Interval - This setting is used to set the

days between regeneration in time clock mode. It is also

active in meter or Aqua-Sensor

®

mode if the time clock

backup DIP switch # 10 is set to on. The display will

show “REGEN” icon and “dAYS” as well as the numbers

to change. Adjust the value with the “Up” or “Down”

keys.

Pressing the “Program” key will save the setting and move to the next programming step.

• Hardness Setting - This setting is used to set the

hardness (grains) of the influent water supply. For English

Units the display will first show “Hard” for two seconds

and then display the Hardness default (or the previously

programmed value). Adjust the value with the “Up” or

“Down” keys.

(These settings will not get saved to EEPROM until the ‘Program’ key is pressed while at the

‘View’ programming step)

• Iron Setting (flow meter only) - This setting is used

to set the iron level of the influent water supply. The

display will show “Iron” in the left most digits and the iron

default setting (or the previously programmed value) in the

far right digit. The display will only appear if a flow meter

is connected to the circuit board and the control is set to

Gold. If the iron level is set to “Y”, the Efficiency Mode is

inactive. Adjust the value with the “Up” or “Down” keys.

Pressing the “Program” key will temporarily store the setting and move to the next programming

step. (This setting will not get saved to EEPROM until the ‘Program’ key is pressed while at the

‘View’ programming step)

• Pressure Setting - This setting is used to set the influent

water pressure. The display will show “LowP” in the

left most digits and the pressure default setting in the far

right digit. If the pressure is less than 40 psi, chose “Y”.

By choosing “Y” the brine rinse time will be extended.

Adjust the value with the “Up” or “Down” keys.

Pressing the “Program” key will temporarily store the setting and move to the next programming step.

• Salt Type (flow meter only) - This setting is used to select the regeneration salt type

(softener mode only). This display will only appear if dips# 3 & 4 are set to Gold, Platinum, or

Other. The display will show “SALt” for 2 seconds. Then display the default ‘NACL’. Pushing

the “Up” or “Down” keys will change to ‘KCL’.

Pressing the “Program” key will temporarily store the setting and move to the next programming

step. (This setting will not get saved to EEPROM until the ‘program’ key is pressed while at the

‘View’ programming step)