The Culligan

®

AccuSoft

®

Plus circuit board controls all the softener functions. These settings are

programmed at the time of installation. The following is a list of all the microprocessor functions in

the event that any of the settings need to be adjusted.

A further description of each programming setting and the corresponding display is outlined below.

For a display that has an icon that is displayed solid for the 2 second time period prior to bringing

up the settings, the settings menu can be reached prior to the two second time out by pressing the

“Up” or “Down” key.

• Beeper Setting - This setting is used to turn the beeper

on or off for each key press actuation. The display will

show “bEEP X” where X is either “Y” or “N”. The “Y”

or “N” will be toggled with the “Up” and “Down” keys.

Setting the Beep option to “N” will only disable the

beeper for key press actuation. The beeper will still be

active for error and alarm codes.

Pressing the “Program” key will save the setting and move to the next programming step.

• Time of Day - This setting is used to program the

current time of day. When in this step the display will first

show “tod” for two seconds.

After “tod” is displayed, “12:00 PM” will display (or the

current set time if already programmed) and the minutes

will flash. The minutes are adjusted with the “Up” or

“Down” key until the correct value is displayed.

Press the “Regen” key to flash the hours. Adjust with the “Up” or “Down” key until the correct

time is displayed.

Pressing the “Program” key will save setting and move to the next programming step. Pressing

“Regen” will move back to the minutes adjust.

• Time of Regeneration - This setting is used to

program the time at which a regeneration is to occur in

the delay mode, or in immediate mode with time clock

backup on. The display will first show “tor” for two

seconds.

After “tor” is shown the display will then show the

default of 2:00 AM (or the current programmed time of

regeneration if already set). The time can be adjusted in

30 minute increments by pressing the “Up” or “Down”

keys.

Pressing the “Program” key will save the setting and move

to the next programming step.