Culligan Gold Series User Manual

Page 18

Advertising
background image

Aqua-Sensor

®

Probe and Soft-Minder

®

Meter Connection

To connect the probe or meter leads refer to Figure 10 and proceed as follows:
• Remove the timer case from the back plate.
• Snap the circuit board holding plate off the back plate to provide access to the back of the

circuit board.

• Remove the plastic plug from the backplate.
• Slip the sensor probe lead or meter cable through the hole and toward the circuit board.

• Connect the lead to the circuit board. The Aqua-Sensor probe terminal is labeled “Aqua-Sensor”

while the Soft-Minder meter terminal is labeled “Flow Meter”.

• Pull any excess cable wire back out of the enclosure, and route the wiring inside the enclosure to

avoid any interference with moving parts.

• Locate the strain relief bushing in the parts pack. Place it on the cable at the point of entry to the

rear of the timer plate and push it into the hole.

18

Note: The strain relief located on the back of the wire connection for the Aqua-Sensor

®

probe may have to be removed in order to fit it through the backplate. Replace the strain

relief if you need to remove it for assembly.

Note: The wire connectors must be connected to the circuit board properly. The wires must

exit the plug-in connector opposite of the raised white base of the circuit board connector.

Failure to properly connect any of the connectors will result in a malfunction of the circuit

board operation.

Dip Switches

Optional Battery

Power

Motor

Cam Switches

Aqua-Sensor

Soft-Minder Meter

Figure 10