6. Aqua-Sensor Installation (optional device)

A. Measure the sensor cable length as shown in Figure 2 and Table 1.
B. Loosen the small Aqua-Sensor Plug
C. Moisten the cable sheath and slide the cable grip up or down to the proper cable length.
D. Tighten the small Aqua-Sensor plug so that the fitting cannot slide along the cable.
E. Insert the probe and cable through the Aqua-Sensor port.

7. Load the tank with the Cullex

®

ion exchange resin. Leveling is not required. Remove the funnel.

8. Install the inlet strainer making sure to thread the strainer in until it bottoms out on the thread.

Failure to install the strainer correctly can cause the control to leak.

Mount the Control Valve

See Figure 3 for a visual on mounting the control valve to the

tank.
• Assemble the o-rings, located in the parts pack, to the tank

adapter.

• The valve adapter o-ring sits on the first step on the

adapter. See Figure 13.

• Lubricate only the top o-ring on the tank adapter, and the

outlet manifold o-ring with silicone lubricant.

• Screw the adapter into the tank until the adapter bottoms

out on the tank flange.

14

Note: There must be no kinks or bends in the cable.

Note: Do not push the top o-ring down to the flange

surface on the adapter.
Note: The larger of the two o-rings in the parts

part goes between the adapter and the valve, do

not stretch the smaller o-ring onto the top of the tank

adapter.

Dimension “X” is the exposed length the Aqua-Sensor

cord (cord length from the Aqua-Sensor plug to the

circuit board connector). You can then verify the

Aqua-Sensor probe is inserted to the proper depth by

confirming dimension “X” is at the corrected length.

X

Y

9” Quadra-Hull Tank

34 1/2”

40”

10” Quadra-Hull Tank 30 1/2”

44”

12” Quadra-Hull Tank 32 1/2”

42”

14” Quadra-Hull Tank 22 1/2”

52”

Table 1

Small
Aqua-Sensor

¤

Plug

Figure 3

Figure 5

Valve - Adapter

O-Ring

Tank Adapter

Adapter -

Tank O-Ring

Tank Clamp

Tank

Clamp

Figure 4

Note: The adapter only needs to be tightened hand-

tight to the tank flange.