Specifications, Culligan gold series, Water conditioners with aqua-sensor – Culligan Gold Series User Manual

Page 4: Device or soft-minder, Meter

Advertising
background image

Culligan Gold Series

Water Conditioners with

Aqua-Sensor

®

Device or Soft-Minder

®

Meter

9” Model

10” Model

12” Model

14” Model

Control Valve

1” 5-cycle

Reinforced

Thermoplastic

1” 5-cycle

Reinforced

Thermoplastic

1” 5-cycle

Reinforced

Thermoplastic

1” 5-cycle

Reinforced

Thermoplastic

Overall Conditioner Height

54 in

60 in

58 in

71 in

Media Tank Design

Quadra-Hull

Quadra-Hull

Quadra-Hull

Quadra-Hull

Media Tank Dimensions

(Dia x Ht)

9 x 48 in

10 x 54 in

12 x 52 in

14 x 65 in

Salt Storage Tank Dimensions

(Dia x Ht)

16 x 43 in

18 x 43 in

18 x 43 in

24 x 42 in

Exchange Media, Type and

Quantity

Cullex

®

Media,

1.0 ft

3

Cullex Media,

1.5 ft

3

Cullex Media,

2.0 ft

3

Cullex Media,

3.0 ft

3

Underbedding, Type and Quantity

Cullsan

®

Underbedding,

12 lb

Cullsan

Underbedding,

15 lb

Cullsan

Underbedding,

16 lb

Cullsan

Underbedding,

25 lb

Exchange Capacity @ Salt

Dosage Per Recharge

19,086 gr @ 4.0 lb

28,629 gr @ 6.0 lb

35,614 gr @ 8.0 lb

53,540 gr @

12.0 lb

26,301 gr @ 8.0 lb

39,451 gr @

12.0 lb

51,659 gr @

16.0 lb

77,660 gr @

24.0 lb

30,787 gr @

12.0 lb

46,180 gr @

18.0 lb

60,532 gr @

24.0 lb

90,986 gr @

36.0 lb

Efficiency at rated salt dosage

1, 6

4,770 gr/lb @

4 lb salt dosage

4,770 gr/lb @

6 lb salt dosage

4,450 gr/lb @

7 lb salt dosage

4,460 gr/lb @

12 lb salt dosage

Freeboard to Media

2

14.5 in

14.5 in

20 in

25 in

Freeboard to Underbedding

3

44.5 in

47.5 in

46 in

59 in

Salt Storage Capacity

250 lb or 375 lb

375 lb

375 lb

600 lb

Rated Service Flow @ Pressure

Drop

9.0 gpm @ 14 psi

9.4 gpm @ 15 psi

10.0 gpm @ 15 psi

10.6 gpm @ 15 psi

Total Hardness, Maximum

75 gpg

99 gpg

99 gpg

99 gpg

Total Iron, Maximum

5 ppm

5 ppm

5 ppm

5 ppm

Hardness to Iron Ratio, Min.

8 gpg to 1 ppm

8 gpg to 1 ppm

8 gpg to 1 ppm

8 gpg to 1 ppm

Operating Pressure

20-125 psi

20-125 psi

20-125 psi

20-125 psi

Operating Pressure (Canada)

20-90 psi

20-90 psi

20-90 psi

20-90 psi

Operating Temperature

33-120°F

33-120°F

33-120°F

33-120°F

Electrical Requirements

24V/60 Hz

24V/60 Hz

24V/60 Hz

24V/60 Hz

Electrical Power Consumption,

Min/Max

3 Watts/ 35 Watts

3 Watts/ 35 Watts

3 Watts/ 35 Watts

3 Watts/ 35 Watts

Drain Flow, Maximum

4

1.6 gpm

1.6 gpm

2.6 gpm

6.6 gpm

Recharge Time, Average

5

68 min

57 min

52 min

66 min

Recharge Water Consumption,

Average

5

35 gal

46 gal

51 gal

176 gal

1

The efficiency rated dosage is only valid at the 4 lb. salt dosage for the 9” model, 6 lb. salt dosage for the 10” model, 7 lb.

salt dosage for 12” model and 12 lb. salt dosage for 14” model and is efficiency rated according to NSF/ANSI Standard 44.

2 Measured from top of media to top surface of tank threads (backwashed and drained).
3 Measured from top of underbedding to top of inlet fitting.
4 Backwash at 120 psi (830 kPa).
5 10 minute backwash, 4 lb. (1.8 kg) 9” model, 6 lb. (2.7 kg) 10” model, 7 lb. 12” model or 12 lb. 14” model salt dosage at

30 psi (204 kPa).

Specifications

4

Advertising