Solvline SG-1160 User Manual

Page 33

Advertising
background image


SerialGate User Guide

33

Menu

Default

Descriptions

SNMP

v1/v2/v3

Agent

Disable

Enable or disable Simple Network Management Protocol (SNMP)

support. (Options : Disable/Enable)

V1/2

Attribution

ReadOnly

SNMP V1/2 Attributes can read and write by SNMP Agent.

In order to read attributes only, change the feature to "ReadOnly".

In order to read and write attributes, change the feature to

"ReadWrite". (Options : ReadOnly/ ReadWrite)

V3 Attribution

ReadOnly

SNMP V3 Attributes can read and write by SNMP Agent.

In order to read attributes only, change the feature to "ReadOnly".

In order to read and write attributes, change the feature to

"ReadWrite". (Options : ReadOnly/ ReadWrite)

V3 Username/

Password

serialgate

/

administrator

Configure the Username and the password when use SNMP V3.

The Password is at least 8 character string

TRAP IP/ Port

0.0.0.0

/162

Configure the server IP address and Port which receive the TRAP

information.

System reset

notification

Enable

If Enable is selected, notify the

“System reset info.”

(Option : Enable, Disable)

Port connect

notification

Disable

If Enable is selected, notify the

“Serial Port opened info.”

(Option : Enable, Disable)

Port

disconnect

notification

Disable

If Enable is selected, notify the

“Serial Port Closed info.”

(Option : Enable, Disable)