I N S T R U C T I O N M A N U A L • M O D E L F M P O W E R S U P P LY

MODE CODES DISPLAY

The power supply is shipped with blank programs, so all data and parameters

must be input by the customer. On initial start-up, the default mode selected

is the Time-Based cycle. Press the INFO key four times and the following

“Mode Codes” display will appear on the LCD screen:

DEFAULT SETTINGS

MODE CODES: FUNCTION ABBREVIATIONS

Following is a complete list of mode code abbreviations that will appear in

eight positions on the LCD display and their corresponding meanings.

1st Position T1 = Ultrasonics are turned on following termination of delay

time or pre-trigger

or

FT = Ultrasonics actuated when trigger force has been

reached

2nd Position ZT = Time-based welding

or

EN = Constant energy welding

3rd Position NB = Normal operation (no rotary table)

or

RT = Rotary table control and operation provided by

microprocessor

4th Position IS = Rotary table pulse control

or

DS = Rotary table continuous signal control with

acknowledgement

5th Position U

= Afterpulse Timer (T4) operational (Not a default)

or

blank

6th Position 1

= Normal Timer operation

7th Position 48 = Baud rate of 4800 for optional printer

8th Position M

= Manual, dual palm switch actuation

or

A

= Automatic impulse actuation

FT ZT NB IS 1 48 M

Force

Triggering

Time-Based

Welding

Rotary Table

Pulse Control

Baud Rate of

4800 for Printer

Manual Palm

Button Start

Normal Timer

Operation

Normal

Operation