I N S T R U C T I O N M A N U A L • M O D E L F M P O W E R S U P P LY

Pre-triggering is accomplished by setting T1 to 0.00 sec, thus continuing the

calibration pulse until T2 is actuated by the horn contacting the workpiece.

The Delay Timer (T1) can only be set or changed when Delay Timer

Triggering (T1) has been selected. The Delay Timer is not operational when

the Force Triggering function (FT) has been selected. Attempts to access T1

when the Force Trigger function has been selected will result in the following

display:

The Weld Timer (T2) can only be set or changed when Time-Based operation

(ZT) has been selected. The Weld Timer is not operational when the Constant

Energy function (EN) has been selected. Attempts to access T2 when the

Constant Energy function has been selected will result in the following

display:

If no timer values are to be changed, press the ENTER key twice (providing

that a time value is displayed) to return to system status READY.

SELECTING AND SETTING THE AFTERPULSE TIMER

In some applications involving staking, spot welding, or a vacuum horn, the

completed assembly may remain attached to the horn. In such instances, the

Afterpulse Timer (T4) can be used to actuate the ultrasonics briefly to release

the assembly as the press retracts to rest position.

To use the Afterpulse Timer (T4), press the INFO key four times to display the

current Mode Codes, for example, T1 ZT NB IS 1 48 M. Press the numerical

key 5 and the letter “U” will appear in the fifth position of the LCD display

between “IS” and “1,” indicating that the Afterpulse Timer (T4) is operational.

The new display will now appear as follows:

Once the Afterpulse Timer is operational, parameters for it may be entered in

the same manner as for all timers: press the Timer key and when prompted,

press the corresponding numerical key (4); then use the CE and numerical

keys to select the value desired.

To cancel operation of the Afterpulse Timer (T4), follow the same procedure

described above to select the function. (The numerical key 5 acts as a toggle

NOTE: T1 should be

selected and set at 0.00

seconds only when pre-

triggering is required. Pre-

triggering during normal

welding operations can

result in surface marking.

T I M E R 1 M O D E I S O F F !

U S - T I M E M O D E I S O F F !

FT EN NB IS 1 48 A

NOTE: If the Afterpulse

Timer is not in use, (which

is the case if the Mode

Code function “U” is not

displayed), T4 should be

cleared so that the

displayed value is 0.00 sec.

Although the Afterpulse

Timer is not operational,

any value set for T4 will

extend the Hold Timer (T3)

duration by that value.