COUPLING FORCE MEASUREMENT (Model 1098 only)

To measure the actual horn coupling force, turn the head down key switch

clockwise. Then, as the head is descending, press the F TRIGGER key and

keep it depressed until the horn contacts the parts.

The coupling force will be displayed on the LCD screen as a percentage of

the maximum available force. (100% = 50 Psig = 245 Ibs. =1,090 Newtons)

Release the head advance control(s) to terminate measurement.

Because of the characteristics of the piezoelectric load cell, the display will be

accurate only if the temperature remains constant and the period of

measurement does not exceed 30 seconds.

If a 30 second duration is

exceeded, release the head advance control and repeat the procedure above.

CLEAR PARAMETERS

To cancel all variable parameters and release keypad security, press the

INFO and F TRIGGER keys simultaneously when “SONICS & MATERIALS”

appears on the LCD screen at start-up. The power supply will return to normal

Force Trigger Operation with Delay Triggering mode.

All keypad LED’s will light up and stay illuminated until the INFO and F

TRIGGER keys are released and the unit is turned Off.

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

I N S T R U C T I O N M A N U A L • M O D E L F M P O W E R S U P P LY

41

The F TRIGGER key must

be depressed before the

horn makes contact or an

invalid force measurement,

or the value “0%,” will be

displayed.

Advertising