Sonics FM User Manual

Page 37

Advertising
background image

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

36

I N S T R U C T I O N M A N U A L • M O D E L F M P O W E R S U P P LY

Constant energy mode with variable force triggering

Power Supply

Mode Codes

Program Version

Output Rating

SONICS AND MATERIALS

V3.0 845-73

1500W

FT EN NB IS 1 48 M

Trigger Force

Trigger (F) = 2%

Energy Set-Value

REF =

91.0 Ws

+ LIM = 0.20 sec

Upper Limit (Time)

Hold Timer

Timer 3

=

0.25 sec

– LIM = 0.10 sec

Lower Limit (Time)

Afterpulse Timer

Timer 4

=

0.00 sec

CAL PULSE = ON

Timer 5

=

0.25 sec

BOOSTER GAIN = 1.50

HORN NUMBER: 123

Pressure 30.00 Psig

0.17 sec

Actual Weld Cycle Duration

Assembly Number

100

91.2 Ws

Actual energy delivered

Percentage of available

65%P max

power used

P

100%

50%

0%

0

0.05

0.10

0.15

0.20

0.25 Sec

Idle Losses For Converter,
Booster and Horn