I N S T R U C T I O N M A N U A L • M O D E L F M P O W E R S U P P LY

37

The keypad is not functional during the time a printout is being made until a

short audible tone is heard and the LCD returns to system status “READY.”

Printing can be stopped at any time by pressing any key. The printer will

continue printing, however, until the data stored in the buffer has been printed.

Time axis plot lengths of 250 ms, 500 ms, 1 second, 5 seconds and 10

seconds are available for printout. The time axis desired must be specified

prior to the assembly cycle, as follows.

Press the INFO key five times until the following display appears on the LCD

screen:

The red LED in the corner or the CE key indicates that it is functional and

therefore, the displayed value can be cancelled and changed.

Press the CE key and then key in the appropriate numerical code (see below)

for the Time Axis Plot Length desired. Acknowledge the entry by pressing the

ENTER key or wait 30 seconds for automatic acceptance.

GRAPH HEADER

In addition to cycle parameters, the printout will also include readings for Air

Pressure, Cal Pulse, Booster Gain and Horn Number. These values may be

entered through the keypad. The printout readings are reference values only;

i.e., if the gauge pressure setting reads 45 psig and the printout reads

“PRESSURE 20 PSIG”, the parts will be welded with 45 psig. The same

applies for “Booster Gain” and “Horn Number.”

G R A P H T I M E A X I S

CODE

TIME AXIS LENGTH

02

250ms

05

500ms

10

1 sec

50

5 sec

99

10 sec