8.4. Connection of the Terminal Plate to the Main Rack (JP-0410)

Use shielded, heat-resistant, twisted paired cable for connection.
Connect the JP-0410's front-mounted terminal block and remote control unit's terminal plate.
The maximum cable length between main rack and remote control unit is 800 m. However, the distance may
be shorter than 800 m depending on the type and zone numbers of remote control units.

8.4.1. Maximum line resistance

Zone numbers Power cable (1 pair) Control cable (4 pairs)

10

Under 5

Under 50

20

Under 3

Under 50

30

Under 2.5

Under 50

40

Under 1.5

Under 50

50 -90

Under 1

Under 50

Over 100

Under 0.5

Under 50

8.4.2. Multiple remote control units connections

• Be sure to branch individual cables at the main rack when connecting multiple remote control units.

Main Rack

Remote control unit

Remote control unit

Remote control unit

Main Rack

Remote control unit

Remote control unit

Remote control unit

• Up to eight remote control units can be connected. Because the power is supplied from the main rack, the

Expansion DC Power Supply Panel or Emergency Power Supply Panel may have to be additionally
mounted in the main rack. For details, refer to the sections "Emergency Power Supply Panel DS-029B
Connection" and "DC Power Supply Panel Connection" in the Installation Manual - Basic Installation for the
FS-970 Series.