8.5.2. Setting of the number of Expansion Control Panels EP-029

Use SW202's switches No. 4 - No. 8 to set the number of Expansion Control Panels to be connected. The
number is set for "0" at the factory.

ON

OFF

4 5 6 7 8

No. of units 0

ON

OFF

4 5 6 7 8

No. of units 1

ON

OFF

4 5 6 7 8

No. of units 15

ON

OFF

4 5 6 7 8

No. of units 16

ON

OFF

4 5 6 7 8

No. of units 2

8.5.3. Remote control mode setting

Use SW202's switch No. 1 to set the remote control mode. The switch is set to the OFF position (Emergency
broadcast mode). Leave the switch as it is.

8.5.4. Voice operation guide setting

Whether or not to enable the voice operation guide function in emergency situations is set here.
Note: The voice operation guide is different from voice alarms.

Use SW202's switch No. 2 to set the voice operation guide. The ON position disables the function, and the
OFF position enables it.

Normally, set the switch to the OFF position (factory-preset position).