8.5.5. Shift switch setting

Use SW201's switches No. 1 - No. 4 and SW202's switch No. 3 to set the shift switch. The shift switch setting
is necessary for the system which controls broadcast in multiple buildings from a central control room. The
above switches are all set for OFF at the factory.

Shown below are the installation example and shift switch settings required for that installation.

[Installation example]

Building A

Building B

Main rack

(50 zones)

RM

(20 zones)

RM

Building C

(40 zones)

RM

Note: [RM] represents a remote control unit.

Main rack (system)

EP-0510

EP-029-10

EP-029-20

EP-029-10

EP-029
Address No.

0

1

2

For Building A

EP-029-10

EP-029-10

3

4

For Building B

EP-029-10

EP-029-20

EP-029-10

5

6

7

For Building C

Building A remote control unit

EP-059R

EP-029-10

EP-029-20

EP-029-10

EP-029
Address No.

0

1

2

SW201
SW202

Building B remote control unit

EP-059R

EP-029-10

EP-029
Address No.

4

SW201
SW202

Building C remote control unit

EP-059R

EP-029-20

EP-029-10

EP-029
Address No.

6

7

SW201
SW202

EP-059R
Address No.: 0

EP-059R
Address No.: 1

EP-059R
Address No.: 2

EP-059R Address No.: 0
(SW201 No. 6 - No. 8)

EP-029 shift switch: Invalid (OFF)
(SW202 No. 3)

No. of EP-029 units: 3
(SW202 No. 4 - No. 8)

EP-059R Address No.: 1
(SW201 No. 6 - No. 8)

EP-029 shift switch: Valid (ON)
(SW202 No. 3)

EP-029 shift switch (No.): 3
(SW201 No. 1 - No.4)

No. of EP-029 units: 1
(SW202 No. 4 - No. 8)

EP-059R Address No.: 2
(SW201 No. 6 - No. 8)

EP-029 shift switch: Valid (ON)
(SW202 No. 3)

EP-029 shift switch (No.): 5
(SW201 No. 1 - No.4)

No. of EP-029 units: 2
(SW202 No. 4 - No. 8)

Advertising