background image

Page 6-5

5. Press the KEY TEST soft key.

Press any key except CLEAR to see the key code; see table below for the
proper key code.

6. Press the CLEAR key to exit the test.

Scale reverts back to Service screen; press the CLEAR key to return to
normal operating mode.

Key

Key Code

Key

Key Code

Screen Up

12

0 0

S1 14 1 1
S2 15 2 2

Screen Down

13

3 3

S3 16 4 4
S4 17 5 5

F2 22 6 6

Auto Hold

20

7 7

F1 21 8 8

Print 19 9 9

Zero Scale

18

Enter 11

6.2.4 How to Enable the Postage Meter Interface

The VP-70 can interface to select Francotyp Postallia postage meters. By default
the postage meter interface is turned off. To enable the meter interface you must
contact the factory to obtain a unique 10-digit setting code. Only scales used by
the United States Postal Service are eligible to obtain a setting code.

1. Press the F1 key.
2. Press the SCREEN DOWN key.
3. Press the SERVICE soft key.
4. At the password prompt key in (336699) then press ENTER.
5. Press the SCREEN DOWN key two times.
6. Press the MTR ENABLE soft key.
7. Press the ON soft key.
8. At the prompt key in the 10-digit setting code then press ENTER.
9. Press the CLEAR key to save and exit.

6.2.5 How to perform a Postage Meter Test

The Meter Test can be used to troubleshoot or check the postage meter
connection.

1. Press the F1 key.
2. Press the SCREEN DOWN key.
3. Press the SERVICE soft key.
4. At the password prompt key in (336699) then press ENTER.
5. Press the MTR TEST soft key.
6. The scale will set the meter for a $1.20 value.