background image

2-1

2.0 GETTING

STARTED

After unpacking the scale, a small amount of preparation is required before the scale can be
used for mailing or shipping. Please refer to Figure 2-1 below as needed.

Figure 2-1: VP-70 Rear Panel

Step 1. Lift the stainless steel platform off the scale and discard the shipping cardboard.

Place the platform back onto the scale.

Step 2. Position the scale in its area of intended use. Observe the following guidelines

for suitable location.

1. Choose a firm and stable table, counter, or other surface.

2. Do not share an AC outlet with electrical noise producing equipment, such as

refrigeration units. This includes products with electrical motors and/or relays.

3. Do not place the scale in an area with changing ambient temperature and/or high

humidity.

4. Do not place the scale in an area prone to exposure to direct sunlight, wind, or dust.

5. Do not place the scale in an area with vibrating equipment.

Step 3. Install the AC Adapter.

1. After placing the scale in its area of use, locate the Model A41408 AC Adapter.

2. Connect the female end of the AC Adapter to the connector on the rear of scale,

and then plug the adapter into an AC outlet.

Step 4. Adjust the leveling feet so that the scale is level and not “rocking” corner to

corner.

Step 5. Turn the scale ON to begin the initialization.

Step 6. Initialization - The first time the scale is turned on you will be required to enter

your origination ZIP Code.

1. When the AC power switch is placed “ON” position, the scale prompts for your

“Origin ZIP Code”.

2. Enter the first three digits of the ZIP Code from which all items will be mailed. There

is no need to press the ENTER key.