6.2.6 How to set the Meter Type

The VP-70 can interface to select Francotyp Postallia postage meters. The scale
will attempt to automatically set the meter type, however use the steps below to
manually set the meter type.

1. Press the F1 key.
2. Press the SCREEN DOWN key.
3. Press the SERVICE soft key.
4. At the password prompt key in (336699) then press ENTER.
5. Press the MTR TYPE soft key.
6. Press the appropriate soft key that corresponds to the type of meter

connected to the scale.

7. Press ENTER to save and exit.

6.2.7 How to set the Meter Mode

The VP-70 by default sets the meter automatically when a rate is displayed. If
desired the meter can be set manually when a rate is displayed by pressing the
ENTER key.

1. Press the F1 key.
2. Press the SCREEN DOWN key.
3. Press the SERVICE soft key.
4. At the password prompt key in (336699) then press ENTER.
5. Press the SCREEN DOWN key.
6. Press the MTR MODE soft key.
7. Select either AUTO or MANUAL by pressing the corresponding soft key.
8. Press CLEAR to save and exit.

6.2.8 How to change the Scale Capacity / Resolution

The scale can be configured to operate with several different resolution settings.
Below is a list of the different settings.

• 0-7 lb x 0.1 oz, 7-70 lb x 0.5 oz (Factory Default Setting)

• 0-7 lb x 0.1 oz, 7-70 lb x 0.2 oz

• 0-7 lb x 0.05 oz, 7-70 lb x 0.2 oz

• 0-7 lb x 0.01 oz, 7-70 lb x 0.1 oz (Special Rate Test Mode Only)


1. Press the F1 key.
2. Press the SCREEN DOWN key.
3. Press the SERVICE soft key.
4. At the password prompt key in (336699) then press ENTER.
5. Press the SCREEN DOWN key.
6. Press the CAPACITY soft key.
7. Press the soft key that corresponds to the capacity / resolution desired.
8. Press the ENTER key to save and exit.