4 commands – Triner Scale TMU-295 User Manual

Page 44

Advertising
background image

5-4

Commands

• This command should not be used within the data sequence of

another command that consists of 2 or more bytes. For example,

If you attempt to transmit ESC 3 n to the printer, but DTR (DSR
for the host computer) goes to MARK before n is transmitted
and then DLE EOT 3 interrupts before n is received, the code
<10>H for DLE EOT 3 is processed as the code for ESC 3
<10>H.

• When Auto Status Back (ASB) is enabled using the GS a

command, the status transmitted by the DLE EOT command and
the ASB status must be differentiated.

• If the n is out of the specified range, the printer ignores this

command.

n = 1: Printer status

n = 2: Off-line status

Bit Off/On

Hex Decimal

Function

0

Off

00

0

Not used. Fixed to Off.

1

On

02

2

Not used. Fixed to On.

2

Off

00

0

Drawer kick-out signal is LOW (connector pin 3)

On

04

4

Drawer kick-out signal is HIGH (connector pin 3)

3

Off

00

0

On-line.

On

08

8

Off-line.

4

On

10

16

Not used. Fixed to On.

5

Off

00

0

Undefined.

On

20

32

Undefined.

6

Off

00

0

Undefined.

On

40

64

Undefined.

7

Off

00

0

Not used. Fixed to Off.

Bit

Off/On

Hex

Decimal

Function

0

Off

00

0

Not used. Fixed to Off.

1

On

02

2

Not used. Fixed to On.

2

Off

00

0

Undefined.

On

04 4

Undefined.

Advertising