Triner Scale TMU-295 User Manual

Page 56

Advertising
background image

5-16

Commands

[Format]

ASCII

ESC K

n

Hex 1B

4B

n

Decimal 27

75

n

[Range]

0

n

255

[Description] Prints the data in the print buffer and feeds the paper by n/60 inches

in the reverse direction.

[Notes]

• This command is available only in standard mode.
• The setting values do not remain.
• After printing is completed, this command sets the print position

to the beginning of the line.

ESC L

[Name]

Select page mode

[Format]

ASCII

ESC

L

Hex

1B

4C

Decimal

27

76

[Description] Switches from standard mode to page mode.
[Notes]

• This command is enabled only when input at the beginning of a

line.

• This command is available only in standard mode.
• After printing by FF is completed, the printer returns to standard

mode.

• This command sets the position where data is buffered to the

position specified by ESC T within the printable area defined by
ESC W.

• In page mode, the printer buffer receives data in the printable area

specified by ESC W and prints the data collectively upon receipt
of FF command. The print and line feed commands, such as LF,
ESC J, ESC K, ESC d, and ESC e, only move the print start
position from which subsequent data is buffered and do not
perform actual printing.

• In page mode, the printer porcesses data referring to normal dot.

Therefore, be careful when using half dot in standard mode.

• Only character fonts with normal dot configuration are available.
• This command switches the settings for the following commands

(in which the values can be set independently in standard mode
and page mode) to those for page mode:

Set character spacing: ESC SP
Select 1/6-inch line spacing: ESC 2
Set line spacing: ESC 3

In page mode, the following commands are ignored.

Print and reverse feed n lines: ESC e
Print and reverse feed: ESC K