Commands

[Notes]

• When DTR/DSR control is selected, the printer transmits only 1

byte after confirming that the host is ready to receive data (DSR
signal is SPACE). If the host computer is not ready to receive data
(DSR signal is MARK), the printer waits until the host is ready.
When XON/XOFF control is selected, the printer transmits only 1
byte without confirming the condition of the DSR signal.

• The ROM version may be changed.
• When Auto Status Back (ASB) is enabled using GS a, the status

transmitted by GS I and the ASB status must be differentiated.

• When n is out of the specified range, this command is ignored.

GS a n

[Name]

Enable/Disable Automatic Status Back

[Format]

ASCII

GS

a

n

Hex

1D

61

n

Decimal

29

97

n

[Range]

0

n

255

[Description] Enables or disables ASB and specifies the status items to include,

using n as follows:

3

Off

00

0

Undefined.

On

08

8

Undefined.

4

Off

00

0

Not used. Fixed to Off.

5

Off

00

0

Undefined.

On

20

32

Undefined.

6

Off

00

0

Undefined.

On

40

64

Undefined.

7

Off

00

0

Not used. Fixed to Off.

Bit

Off/On

Hex

Decimal

Status for ASB

0

Off

00

0

Drawer kick-out connector pin 3 status
disabled.

On

0 1

Drawer kick-out connector pin 3 status
enabled.

Bit

Off/On Hex Decimal

Function