30 commands – Triner Scale TMU-295 User Manual

Page 70

Advertising
background image

5-30

Commands

First byte (printer information)

Second byte (error information)

Bit

Off/On

Hex

Decimal

Status for ASB

0

Off

00

0

Not used. Fixed to Off.

1

Off

00

0

Not used. Fixed to Off.

2

Off

00

0

Drawer kick-out connector pin 3 is LOW

On

04

4

Drawer kick-out connector pin 3 is HIGH.

3

Off

00 0

On-line.

On 08

8

Off-line.

4

On

10

16

Not used. Fixed to On.

5

Off

00

0

Not used. Fixed to Off.

6

Off

00

0

Paper feed button is not used.

On

40

64

Paper feed button is used.

7

Off

00

0

Not used. Fixed to Off.

Bit

Off/On

Hex

Decimal

Status for ASB

0

Off 00

0

Undefined.

On 01

1

Undefined.

1

Off 00

0

Undefined.

On 02

2

Undefined.

2

Off 00

0

Undefined.

On 04

4

Undefined.

3

Off

00

0

Undefined.

On

08

8

Undefined.

4

Off

00

0

Not used. Fixed to Off.

5

Off

00

0

No unrecoverable error.

On

20

32

Unrecoverable error.

6

Off 00

0

Undefined.

On

40

64

Undefined.

7

Off

00

0

Not used. Fixed to Off.

Advertising