Commands 5-29 – Triner Scale TMU-295 User Manual

Page 69

Advertising
background image

Commands 5-29

[Notes]

• If n = 0, ASB is disabled.
• ASB is enabled if only one status is selected. The printer

automatically transmits a status of four bytes whenever the status
changes.

• If ASB is enabled while processing this command, the current

status is transmitted with no regulations.

• When transmitting a status, the printer transmits only four bytes

without confirming the condition of the DSR signal.

• Four bytes of status data must be consecutive, except for XOFF

code.

• This command is executed when the data in the receive buffer is

developed. Therefore, there may be a time lag between receiving
this command and transmitting the status, depending on the
receive buffer status.

• When the printer is disabled by ESC =, this command is disabled

but ASB is not disabled.

• When using ESC u, ESC v, GS I or DLE EOT, the status

transmitted by this command, the ASB information, and the status
transmitted by another commands must be differentiated.

• The status to be transmitted are as follows:

1

Off

00

0

On-line/Off-line status disabled.

On

02

2

On-line/Off-line status enabled.

2

Off

00

0

Error status disabled.

On

04

4

Error status enabled.

3

Off

00

0

Undefined.

On

08

8

Undefined.

4

Off

00

0

Undefined.

On

10

16

Undefined.

5

Off

00

0

Slip sensor status disabled.

On

20

32

Slip sensor status enabled.

6

Off

00

0

Undefined.

On

40

64

Undefined.

7

Off

00

0

Undefined.

On

80

128

Undefined.

Bit

Off/On

Hex

Decimal

Status for ASB

Advertising