Cleaning and inspecting the pump heads

+

Service only one side of the pump at a time to avoid the mixing of

parts.

In case, position the pump on edge (place pump onto inlet distributor

or outlet distributor respectively). Support the pump appropriately.

Loosen the union nuts (N) of the hose con-

nections at the pump heads with an open-

ended wrench (w/f 17).

Turn the fittings (Q) with an open-ended

wrench (w/f 14, at outlet w/f 16) to detach

the hoses from the pump heads (1/4 of a

turn at maximum).

+

Do not remove the elbow fittings from the

pump heads; during reassembly a leak may

result.

Inlet side

Fittings and tubing of the different pump models:

ME 16C

MZ 8C

MD 8C

MD 12C

MV 10C