View of the disassembled pump head parts (e. g. MV 10 VARIO)

Cleaning and inspecting the pump heads

valve*
cover plate*
countersunk head screw*
housing
connecting rod

head cover
seal
valve
housing cover

* only MV 10 VARIO

washer
diaphragm
diaphragm support disc
diaphragm clamping disc

➨ Use open-ended wrench, remove screw-in fittings from all

pump heads.

➨ To check the valves use hex key to remove four socket-

head screws from pump head and remove housing cover
with head cover, valves and O-ring (MD 12 / MV 10 only).

☞ Never remove parts by using a spiky or sharp-edged tool

(e.g. screw driver), we recommend to use a rubber mallet or
compressed air (to be blown carefully into port).

➨ Remove head cover carefully from housing cover. Note po-

sition of valves and remove them.

☞ Replace valves if necessary.

☞ Use petroleum ether or industrial solvent to remove depos-

its. Do not inhale.