Print approval, Material, Quantities – Flex FLC Coping User Manual
Page 2: Flexcap flc coping
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
APPROVE)
FLEXCAP FLC COPING
TAPERED VERSION
ANSI/SPRI ES-1 TESTED
Coping cover 12'-0'
(3.65 m) lengths
8" (203 mm) wide
concealed splice plate at
each joint
12" (305 mm) wide
20 ga. (1 mm) galvanized
anchor clips 4'-0" (1.22 m) o.c.
'A'
NOANa-M^ll
\Vm)
Cwsty,
'C
Inside Face
Min. 2 1/4" (57 mm)
Max. 6" (152 mm)
3/8" (10 mm)
space provided for
wall variations
Outside Face
Min. 3" (76 mm)
Max. 6" (152 mm)
Actual wall width
Coping is to be installed per Specifications and Flex's Installation Instruction Dwg. # 28111-3454
- Concealed splice plates are provided with factory applied dual
non- curing sealant strips.
“ Unless otherwise noted, fabrication of miters and accessories
are furnished standard utilizing a non-penetrating quicklock Joint,
then factory sealed watertight.
Fabrication will proceed only after receipt of
signed print approval.
Print Approval:
Architect and/or contractor shall verify all
dimensions, sizes and quantities. All
products to be installed in strict accordance
with Flex's printed instructions.
Approved by:
_____________________________
Date:
_____________________
■ Welded Miters and Accessories
Check one □ Required (surcharge) □ Not applicable
MATERIAL:
Color:
24 Ga. (0.65 mm) Galv.
. .040" (1.01 mm) Alum.
.050" (1.27 mm) Alum.
. .063" (1.60 mm) Alum. Finish:
OTHER________________
QUANTITIES:
__ Lineal Feet (12'-0" (3.65 m) Lengths)
Outside Miters @ (_______
°)
Inside Miters @ (______ °)
Right End Caps
Left End Caps
PROJECT:
ARCHITECT:
ROOFING CONTRACTOR:
REPRESENTATIVE/DISTRIBUTOR:
Customer Service:
Phone: 800^969-0108
Fax:610-916-9501
DATE: 12/13/10
DRN BY: JJC
CKD BY: SAK
SHT.# OF
DWG# 28011-3169
print approval
72