Figure 4s, Kit components, Figuro 47 – Sears 9MPD125L20B1 User Manual

Page 46: Concentric vent dimensional drawing

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

tical termination is preferred. Field supplied pipe and fittings are
required to complete the installation.

Figure 4S

Kit Components

Kit Contents:
3" Rain Cap or 2" Rain Cap
3" Diameter SDR-26 Pipe, 19^2" Long or
4" Diameter SDR-26 Pipe, 37Vs" Long,
2" Diameter SDR-26 Pipe, 31^/s" Long or

2

V

2

" Diameter SDR-26 Pipe, 24" Long,

3" Y Concentric Fitting or 2" Y Concentric Fitting

Nominal 3" or 4" Día.

25-22-03

Vertical & Horizontal Termination

1.

Determine the pipe diameters required for the installation

from Table 13 and Table 14 and Figure 47.

2.

Determine the best location for the termination kit. See

Figure 46 for vertical termination or Figure 46 and
Figure 50 for horizontal termination. Roof termination is

preferred since it is less susceptible to damage, has re­
duced intake contaminants and less visible vent vapor. For
side wall termination, consideration should be given to:

1

)

possible damage from the vapors to plants/shrubs, other
equipment and building materials,

2

) possible damage to

the terminal from foreign objects, 3) wind effects that may
cause recirculation of flue products, debris or light snowand
4) visible vent vapor.

3.

Cut one 5" diameter hole through the structure for the

NAHA001CV Kit or one 4" diameter hole for the
NAHA002CV Kit.

4.

Dimension D may be lengthened to 60" max. or shortened

by cutting the pipes to 12" min. Dimension A will change ac­
cording to D dimension. (See Figure 47)

Figuro 47

Concentric Vent Dimensional
Drawing

EPVC

25-22-03

Model

A*

B

c

D”

NAHA001CV

38'/g

3

W

2

21 7g

NAHA002CV

33%

2

3^7^

16Vg

*

=

Dimension will change accordingly as dimension D is

lengthened or shortened.

= Dimension D may be lengthened to 60" may also be

shortened by cutting the pipes provided in the kit to 12"
minimum

Table 13

Concentric Termination Kit

NAHA001CV & NAHA002CV Venting

Table for *9MPD Models

50,000, 75,000 & 80,000 Btuh Furnaces

NAHA002CV -

35' & (4) 90° elbows with 2" PVC pipe or

NAHA001CV -

65' & (4) 90° elbows with 3" PVC pipe

100,000 Btuh Furnace

NAHA001CV - 35' & (4)

90° elbows with 3" PVC pipe or

NAHA001CV - 65' & (4)

90° elbows with 3” PVC pipe &

Long Vent Kit (See Tech. Manual)

125,000 Btuh Furnace

NAHA001CV -

35' & (4) 90° elbows with 3” PVC pipe

1. Do not include the field supplied 45° elbow in the total elbow

count.

2. If more than four elbows are required, reduce the length of

both the inlet and the exhaust pipes five feet for each

additional elbow used.

3. Elbows are DWV long radius type for 2 ' and 3" vents.

NOTE: Feet of pipe is whichever pipe run is the longest, either
inlet or outlet side.