INSTALLATION STEP 9

Electrical Requirements

To avoid installation difficulties, do not run the

opener at this time.

To reduce the risk of electric shock, your garage door

opener has a grounding type plug with a third

grounding pin. This plug will only fit into a grounding

type outlet. If the plug doesn't fit into the outlet you

have, contact a qualified electrician to install the
proper outlet.

RIGHT

WRONG

If permanent wiring is required by your iocai
code, refer to the following procedure.

To make a permanent connection through the 7/8"
hole in the top of the motor unit:

• Remove the motor unit cover screws and set the

cover aside.

• Remove the attached 3-prong cord.

■ Connect the black (line) wire to the screw on the

brass terminal; the white (neutral) wire to the
screw on the silver terminal; and the ground wire

to the green ground screw. The opener must be

grounded.

• Reinstall the cover.

^WARNING

To prevent possible SERIOUS INJURY or DEATH from
electrocution or fire:
• Be sure power is not connected to the opener, and

disconnect power to circuit BEFORE removing cover to
establish permanent wiring connection.

• Garage door installation and wiring MUST be in

compliance with all local electrical and building codes.

• NEVER use an extension cord, 2-wire adapter, or

change plug in any way to make it fit outlet. Be sure

the opener is grounded.